Jumper Setting
1.CPU Frequency setting Factory Default Setting
Function JP4 (SHORT)
FSB400
1-2, 3-4
FSB533 3-4
2. Compact Flash Master/Slave setting
Function JP3 (SHORT)
Master
1-2
Slave N/C
3. CMOS Operation mode
Function JP6 (SHORT)
CMOS Normal
N/C
CMOS Reset 1-2
To clear the CMOS:
1) Remove AC power from the unit.
2) Open the cabinet.
3) Change the JP6 jumper setting from N/C to 1-2.
4) Wait 1 minute.
5) Change the JP6 jumper setting back to N/C.
6) Close the cabinet.
7) Apply AC power and continue.
4. POWER USB Power setting (Reserved)
Function JP14 (SHORT)
+24V 1-2
+12V 3-4
5. Cash Drawer Power setting
Function JP8 (SHORT)
+12 V
1-2
Cash Drawer 1
+24V 3-4
+12 V
5-6
Cash Drawer 2
+24V 7-8